Summary for Test 2024-03-14-28-4

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 993529
DEA: 11430514
EFIS: 1119000008
DIST-CO-RTE-PM11-SD-15-R31.3/R37.1
Award Date05/27/2022
Closeout DateNot set
Work DescriptionCRCP, FIBER OPTIC CABLE, AND HMA.
Location DescriptionSAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING
QA Service Level1 (Verified on 02/07/2022)

Sample Information

Sample Taken Date03/14/2024 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/14/2024
Sample typeQuality Assurance A brief description of the sampleConcrete Aggs
The quantity of what the sample constitutes3 Bags From where was the sample collectedSource
First name of sampler or witnessed byJesse Last name of sampler or witnessed byGastelum
Title of sampler Telephone number of sampler
Laboratory sample identification24-6637-S Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Mariatta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-00-0000
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-03-14-28
DIME Test ID: 2024-03-14-28-4
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-03-27

Test Results


Number of tests: 3
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 03/21/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.8
Sand reading (test 1): 4
Clay reading (test 2): 4.5
Sand reading (test 2): 3.9
Clay reading (test 3): 4.9
Sand reading (test 3): 3.7
Sand equivalent (test 1): 84
Sand equivalent (test 2): 87
Sand equivalent (test 3): 76
Sand equivalent before temperature correction: 83
Sand equivalent after temperature correction: 83
General comments (publicly viewable) (Max 1000 characters): Fine Aggregate Test results are within specification limits.

Test was verified on 3/27/2024