Summary for Test 2024-03-04-20-1
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 994767 DEA: 043Q5304 EFIS: 0419000221 |
---|---|
DIST-CO-RTE-PM | 04-CC-4,242,680-VAR |
Award Date | 06/27/2023 |
Closeout Date | Not set |
Work Description | POLYESTER CONCRETE OVERLAY, GRIND BRIDGE DECK, & REPLACE JOINT SEALS. |
Location Description | CONTRA COSTA COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 05/10/2023) |
Sample Information
Sample Taken Date | 03/04/2024 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/04/2024 |
Sample type | Quality Control | A brief description of the sample | 2 pints KBP 204, CHP, 8020 |
The quantity of what the sample constitutes | 100 Totes | From where was the sample collected | Source |
First name of sampler or witnessed by | GILBERTO | Last name of sampler or witnessed by | GONZALEZ |
Title of sampler | Quality Control Manager | Telephone number of sampler | 17076245467 |
Laboratory sample identification | 000038KBP | Linked DIME Sample ID | 000038KBP |
The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | 2430891990 |
---|---|---|---|
Batch number | 2430891990 | Mix number | 2430891990 |
Test Details
DIME Sample ID: 2024-03-04-20
DIME Test ID: 2024-03-04-20-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2024-03-25
Test Results
Input Type: Measured
Tester's full name: Mitra Rafiei
Date of test: 03/25/2024
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 19.46
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.09
Volatile content (ASTM D 2369) 30% max: 27.8
Flash point (ASTM D 3828) more than 180 deg F: 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 721
Tack free time, 400 minutes max: 385
General comments (publicly viewable) (Max 1000 characters): Accepted Vendors Results
Test was verified on 3/25/2024 ✔