Summary for Test 2017-05-18-1-3
Test performed: ASTM A775-07b-re14Project Information
Project Identifiers | Project ID: 211854 DEA: 043G0804 EFIS: 0400021272 |
---|---|
DIST-CO-RTE-PM | 04-SON-1-30.5 |
Award Date | 01/20/2017 |
Closeout Date | 02/27/2019 |
Work Description | CONSTRUCT ROADWAY AND SOIL NAIL WALLS |
Location Description | SONOMA COUNTY NEAR FORT ROSS AT 2.6 MILES SOUTH OF FORT ROSS ROAD |
QA Service Level | 1 (Verified on 03/13/2017) |
Sample Information
Sample Taken Date | 05/18/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
Sample type | Quality Assurance | A brief description of the sample | No 8 Gr 75 epoxy coupler |
The quantity of what the sample constitutes | unknown | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 562 440 7716 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Williams Form Eng | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L0805117 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Plain | Rebar Size | 8 |
Nut Specification for Threaded Bar | unknown | System Manufacturer | Williams Form Eng |
Epoxy Coating Color | Purple | Threaded Bar Application | Threaded Bar |
Coating Standards | ASTM A934 epoxy | Bar Heat Number(s) | N/A |
Nut Heat Number(s) | N/A | Bar Lot Number | N/A |
Nut Lot Number | N/A | Coupler Heat Number(s) | 395989 |
Coupler Grade | 75 |
Test Details
DIME Sample ID: 2017-05-18-1
DIME Test ID: 2017-05-18-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Test Release Date: 2017-05-31
Test Results
Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 05/23/2017
Lower spec. limit LSL: 10 mils
Upper spec. limit USL: 15 mils
Bar # for First Bar: no data
Bar # for Second Bar: no data
First Bar Side 1 mean value: 12.85 mils
First Bar Side 2 mean value: 8.6 mils
Second Bar Side 1 mean value: 11.95 mils
Second Bar Side 2 mean value: 11.1 mils
First Bar Mean: 10.73 mils
Second Bar Mean: 11.52 mils
Total mean value: 11.13 mils
General comments (publicly viewable) (Max 1000 characters): Couplers Only
Test was verified on 5/24/2017 ✔