Summary for Test 2024-03-05-12-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 994591
DEA: 081J6704
EFIS: 0818000090
DIST-CO-RTE-PM08-RIV-15-9.4/16.3
Award Date05/04/2023
Closeout DateNot set
Work DescriptionMINOR CONCRETE, MODIFYING SIGNAL AND LIGHTING SYSTEMS, HMA AND JPCP.
Location DescriptionRIVERSIDE COUNTY IN MURRIETA AND WILDOMAR AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF MURRIETA HOT SPRINGS ROAD OVERCROSSING TO BUNDY CANYON ROAD UNDERCROSSING.
QA Service Level1 (Verified on 06/20/2023)

Sample Information

Sample Taken Date03/05/2024 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/06/2024
Sample typeQuality Assurance A brief description of the sampleConcrete Cylinders
The quantity of what the sample constitutes3 From where was the sample collectedJob Site
First name of sampler or witnessed byZaid Last name of sampler or witnessed byHilli
Title of samplerTE Telephone number of sampler
Laboratory sample identification1062-1 Linked DIME Sample ID
The fabricator/manufacturer/facility nameShort Load Concrete Inc. Transportation Laboratory (TL) Number1062-1
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collectedNot Provided The batch plant ticket number from where the sample was collectedNot Provided
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedI15 Clinton Keith NB Off Ramp Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-03-05-12
DIME Test ID: 2024-03-05-12-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-03-20

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 03/15/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Average diameter of cylinder 3: 6.00 in
Maximum load on cylinder 1: 193355 lb
Maximum load on cylinder 2: 188225 lb
Maximum load on cylinder 3: 194465 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 10 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Cross sectional area of cylinder 3: 28.27 in^2
Compressive strength of cylinder 1: 6839.6 psi
Compressive strength of cylinder 2: 6658.1 psi
Compressive strength of cylinder 3: 6878.8 psi
Compressive strength (to nearest 10 psi): 6790 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/20/2024