Summary for Test 2024-03-10-8-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994346 DEA: 033F23U4 EFIS: 0322000243 |
---|---|
DIST-CO-RTE-PM | 03-PLA-80-0.1/2.2,4.9/6.0 |
Award Date | 05/25/2023 |
Closeout Date | Not set |
Work Description | ROADWAY EXCAVATION, PLACE CL2-AB, HMA, STRUCTURAL CONCRETE & RCP. |
Location Description | PLACER COUNTY IN ROSEVILLE FROM 0.1 MILE WEST OF RIVERSIDE AVENUE OVERCROSSING TO 0.3 MILE EAST OF DOUGLAS BOULEVARD OVERCROSSING AND IN ROCKLIN FROM 1.1 MILE WEST OF ROCKLIN ROAD UNDERCROSSING TO ROCKLIN ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 11/09/2022) |
Sample Information
Sample Taken Date | 03/10/2024 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/14/2024 |
Sample type | Quality Assurance | A brief description of the sample | 4 Boxes of Mix |
The quantity of what the sample constitutes | 3/4" HMA-SP 25% RAP | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Dave | Last name of sampler or witnessed by | Drane |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Daily 24-005 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Teichert Perkins | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 1 | HMA Mix Number |
Test Details
DIME Sample ID: 2024-03-10-8
DIME Test ID: 2024-03-10-8-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-03-15
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 03/15/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2361.9 g
Mass Loss: 130.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.72 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.80 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/15/2024 ✔