Summary for Test 2024-03-05-25-4

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 993529
DEA: 11430514
EFIS: 1119000008
DIST-CO-RTE-PM11-SD-15-R31.3/R37.1
Award Date05/27/2022
Closeout DateNot set
Work DescriptionCRCP, FIBER OPTIC CABLE, AND HMA.
Location DescriptionSAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING
QA Service Level1 (Verified on 02/07/2022)

Sample Information

Sample Taken Date03/05/2024 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/06/2024
Sample typeQuality Assurance A brief description of the sample3/4" HMA PSU
The quantity of what the sample constitutes12 boxes From where was the sample collectedSource
First name of sampler or witnessed byJesse Last name of sampler or witnessed byGastelum
Title of sampler Telephone number of sampler
Laboratory sample identification6636-PSU Linked DIME Sample ID
The fabricator/manufacturer/facility nameMM Lake Elsinor Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number53417105

Test Details

DIME Sample ID: 2024-03-05-25
DIME Test ID: 2024-03-05-25-4
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2024-03-15

Test Results


Number of tests: 3
Input Type: Measured
Tester's full name: Daniel Smith / J Seymour
Date of test: 03/08/2024
123
0.000 0.000 0.000
2.47

100.0 %

100.0 %

100.0 %

100.0 %
General comments (publicly viewable) (Max 1000 characters): FAILED HEIGHT Requirement of 115.0 MM +/- .5 MM. Void Pucks tested under 110.0 MM

Test was verified on 3/15/2024