Summary for Test 2023-08-20-16-6
Test performed: CTM 389-19Project Information
Project Identifiers | Project ID: 994543 DEA: 023J7604 EFIS: 0222000081 |
---|---|
DIST-CO-RTE-PM | 02-SHA-273-12.8/14.6 |
Award Date | 04/25/2023 |
Closeout Date | 04/11/2024 |
Work Description | COLD PLANE ASPHALT CONCRETE PAVEMENT AND PLACE RUBBERIZED HMA-G. |
Location Description | SHASTA COUNTY IN REDDING FROM 0.1 MILE NORTH OF CEDARS ROAD/S BONNYVIEW ROAD TO 0.1 MILE NORTH OF BUENAVENTURA BOULEVARD |
QA Service Level | 1 (Verified on 08/07/2023) |
Sample Information
Sample Taken Date | 08/20/2023 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/21/2023 |
Sample type | Production Start-Up | A brief description of the sample | 16 boxes of Lime Treated 1/2-inch RHMA-G (PG 64-16 CR) |
The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D79333 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 866066 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | JMF3513202318 |
Test Details
DIME Sample ID: 2023-08-20-16
DIME Test ID: 2023-08-20-16-6
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2024-03-07
Test Results
Specified number of passes at 12.7 mm: 15000
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 08/31/2023
Test Temperature: 122 F
HMA Production: Field Plant Produced
Compaction Method: SGC Cylindrical Specimen
Binder High PG Grade: no data
Binder Content TWM: no data
Air Void Content: no data
Aggregate Gradation: no data
Type and Amount of Anti-Stripping Additive: 1.0% Lime
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 0.55 mm
Maximum impression at 5000 passes (right wheel): 1.04 mm
Average impression at 5000 passes (left/right avg): 0.8 mm
Maximum impression at 10000 passes (left wheel): 0.69 mm
Maximum impression at 10000 passes (right wheel): 1.25 mm
Average impression at 10000 passes (left/right avg): 0.97 mm
Maximum impression at 15000 passes (left wheel): 0.77 mm
Maximum impression at 15000 passes (right wheel): 1.36 mm
Average impression at 15000 passes (left/right avg): 1.06 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters): Nf>15000,
SIP>15000
Test was verified on 3/7/2024 ✔