Summary for Test 2023-08-20-16-6

Test performed: CTM 389-19

Project Information

Project IdentifiersProject ID: 994543
DEA: 023J7604
EFIS: 0222000081
DIST-CO-RTE-PM02-SHA-273-12.8/14.6
Award Date04/25/2023
Closeout Date04/11/2024
Work DescriptionCOLD PLANE ASPHALT CONCRETE PAVEMENT AND PLACE RUBBERIZED HMA-G.
Location DescriptionSHASTA COUNTY IN REDDING FROM 0.1 MILE NORTH OF CEDARS ROAD/S BONNYVIEW ROAD TO 0.1 MILE NORTH OF BUENAVENTURA BOULEVARD
QA Service Level1 (Verified on 08/07/2023)

Sample Information

Sample Taken Date08/20/2023 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/21/2023
Sample typeProduction Start-Up A brief description of the sample16 boxes of Lime Treated 1/2-inch RHMA-G (PG 64-16 CR)
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byCindy Last name of sampler or witnessed byBryant
Title of sampler Telephone number of sampler
Laboratory sample identificationD79333 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis — Northstate Asphalt (Redding, CA) Transportation Laboratory (TL) Number866066
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberJMF3513202318

Test Details

DIME Sample ID: 2023-08-20-16
DIME Test ID: 2023-08-20-16-6
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2024-03-07

Test Results


Specified number of passes at 12.7 mm: 15000
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 08/31/2023
Test Temperature: 122 F
HMA Production: Field Plant Produced
Compaction Method: SGC Cylindrical Specimen
Binder High PG Grade: no data
Binder Content TWM: no data
Air Void Content: no data
Aggregate Gradation: no data
Type and Amount of Anti-Stripping Additive: 1.0% Lime
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 0.55 mm
Maximum impression at 5000 passes (right wheel): 1.04 mm
Average impression at 5000 passes (left/right avg): 0.8 mm
Maximum impression at 10000 passes (left wheel): 0.69 mm
Maximum impression at 10000 passes (right wheel): 1.25 mm
Average impression at 10000 passes (left/right avg): 0.97 mm
Maximum impression at 15000 passes (left wheel): 0.77 mm
Maximum impression at 15000 passes (right wheel): 1.36 mm
Average impression at 15000 passes (left/right avg): 1.06 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters): Nf>15000, SIP>15000

Test was verified on 3/7/2024