Summary for Test 2024-01-28-20-7
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994903 DEA: 11430244 EFIS: 1118000033 |
---|---|
DIST-CO-RTE-PM | 11-SD,-125-9.3/13.0 |
Award Date | 09/06/2023 |
Closeout Date | Not set |
Work Description | PLACE HMA, RHMA, SLAB REPLACEMENT, AND ELECTRICAL WORK. |
Location Description | SAN DIEGO COUNTY IN AND NEAR LEMON GROVE FROM 0.3 MILE SOUTH OF ELKELTON PLACE UNDERCROSSING TO 0.2 MILE SOUTH OF ROUTE 125/94 SEPARATION |
QA Service Level | 1 (Verified on 11/14/2023) |
Sample Information
Sample Taken Date | 01/28/2024 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/29/2024 |
Sample type | Quality Assurance | A brief description of the sample | 1/2" HMA PSU |
The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Source |
First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0107-PSU | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | 320819 Otay Val |
Test Details
DIME Sample ID: 2024-01-28-20
DIME Test ID: 2024-01-28-20-7
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-03-07
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 03/08/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3885.3 g
Mass of the specimen and specimen basket assembly prior to ignition: 5534.0 g
Mass of HMA Sample prior to ignition: 1648.7 g
Mass Loss: 133.7 g
Mass of aggregate remaining after ignition: 1515.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 8.11 %
General comments (publicly viewable) (Max 1000 characters): RAP Oil Content
Test was verified on 3/7/2024 ✔