Summary for Test 2023-08-20-16-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994543 DEA: 023J7604 EFIS: 0222000081 |
---|---|
DIST-CO-RTE-PM | 02-SHA-273-12.8/14.6 |
Award Date | 04/25/2023 |
Closeout Date | 04/11/2024 |
Work Description | COLD PLANE ASPHALT CONCRETE PAVEMENT AND PLACE RUBBERIZED HMA-G. |
Location Description | SHASTA COUNTY IN REDDING FROM 0.1 MILE NORTH OF CEDARS ROAD/S BONNYVIEW ROAD TO 0.1 MILE NORTH OF BUENAVENTURA BOULEVARD |
QA Service Level | 1 (Verified on 08/07/2023) |
Sample Information
Sample Taken Date | 08/20/2023 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/21/2023 |
Sample type | Production Start-Up | A brief description of the sample | 16 boxes of Lime Treated 1/2-inch RHMA-G (PG 64-16 CR) |
The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D79333 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 866066 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | JMF3513202318 |
Test Details
DIME Sample ID: 2023-08-20-16
DIME Test ID: 2023-08-20-16-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-03-07
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 08/21/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3062.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 4566.2 g
Mass of HMA Sample prior to ignition: 1504.2 g
Mass Loss: 139.8 g
Mass of aggregate remaining after ignition: 1364.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.49 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.20 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 8.60 %
General comments (publicly viewable) (Max 1000 characters): Pb=8.61%
Test was verified on 3/7/2024 ✔