Summary for Test 2024-02-20-9-1

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/20/2024 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/20/2024
Sample typeQuality Control A brief description of the sampleTank 101
The quantity of what the sample constitutes1 of 1 From where was the sample collectedManufacturer
First name of sampler or witnessed byAndromita Last name of sampler or witnessed byAvenetti
Title of sampler Telephone number of sampler
Laboratory sample identification230220-6416-01 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMojave, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number101
Time of sample HMA Supplier
Certified Asphalt SupplierWestern Emulsions Incorporated - Mojave CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-02-20-9
DIME Test ID: 2024-02-20-9-1
Testing Lab: Western Emulsions, Incorporated - Mojave
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2024-03-01

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Luis Torres
Date of test: 03/01/2024
Time of test: no data
Test Temperature: no data
Speed: no data
Spindle size: no data
Torque: no data
Viscosity reading #1 (A) : no data
Viscosity reading #2 (B) : no data
Viscosity reading #3 (C): no data
Average viscosity: 0.423 Pa-s
General comments (publicly viewable) (Max 1000 characters): Submitted from ASCP bulk upload.

Test was verified on 3/1/2024