Summary for Test 2024-02-15-36-2

Test performed: ASTM D412-16r21

Project Information

Project IdentifiersProject ID: 994395
DEA: 070W2704
EFIS: 0721000223
DIST-CO-RTE-PM07-LA-710-10.5/32.5
Award Date02/15/2023
Closeout DateNot set
Work DescriptionPOLYESTER CONCRETE OVERLAY, APPLY METHACRYLATE & REPLACE JOINT SEALS
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM COMPTON CREEK BRIDGE TO UNION STREET OVERCROSSING
QA Service Level1 (Verified on 02/28/2023)

Sample Information

Sample Taken Date02/15/2024 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/23/2024
Sample typeQuality Assurance A brief description of the sampleBearing Pad
The quantity of what the sample constitutes5 From where was the sample collectedManufacturer
First name of sampler or witnessed byVicki Last name of sampler or witnessed bySimon
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameD.S. Brown Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)1067913-1103-1A
Material/Compound/Elastomer IDNA Samples Representing5
Description (size)1 Comments
Description (Number of Shims)7 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)DS Brown
Batch NumberNA

Test Details

DIME Sample ID: 2024-02-15-36
DIME Test ID: 2024-02-15-36-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Test Release Date: 2024-03-07

Test Results


Number of specimens tested: 3
Unit of the Ultimate Tensile Values: lbf per sqr in
Input Type: Calculated
Tester's full name: aauvinen
Date of test: 03/01/2024
UTM: 2kip
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.092
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2786.45 lbf/in^2
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.089
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 2766.42 lbf/in^2
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.091
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2891.75 lbf/in^2
Sample 3 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2786.5 lbf/in^2
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Sample 3

Source: Bluehill Data Point File
Test graph for Sample 1

Source: Bluehill Data Point File
Test graph for Sample 2

Test was verified on 3/7/2024