Summary for Test 2017-05-03-1-62

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212164
DEA: 051J1304
EFIS: 0517000064
DIST-CO-RTE-PM05-MON,MON-1-45.52, 45.4/45.8
Award Date02/16/2017
Closeout Date10/25/2019
Work DescriptionPfeiffer Canyon Emergency Bridge Replacement Project
Location DescriptionHighway 1 at Pfeiffer State Park
QA Service Level1 (Verified on 02/27/2017)

Sample Information

Sample Taken Date05/03/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/05/2017
Sample typeQuality Assurance A brief description of the sampleST-70 Bridge Rail Hardware
The quantity of what the sample constitutes75 From where was the sample collectedDistributor
First name of sampler or witnessed byScott Last name of sampler or witnessed byLeavitt
Title of samplerQA Inspector Telephone number of sampler510 590-0116
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUniversal Industrial Sales Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS28-127-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)NF16100930, CR10411640, 20388020, 21541940, 621391132, 21306330, 10432280 Nut Mfg. Lot Number(s)15-40-006, 16-40-007
Washer Mfg. Lot Number(s)D1782, C7470D, Bolt SpecificationA325, A325, A449
Bolt Length(s)3/4 X 5-1/2, 3/4 X 4-1/2, , , 7/8 X 18, , Nut SpecificationA563, A563
Washer SpecificationF436, F436, FinishHDG, HDG, HDG, HDG, HDG, HDG, HDG
Diameter/Size3/4, 3/4, 3/4, 3/4, 7/8, 7/8, 7/8 Bolt Mfg. Lot NumberBG0609, 762834, 28330
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2017-05-03-1
DIME Test ID: 2017-05-03-1-62
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-05-18

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/11/2017
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
17BS28127177/8\"70931315.52Nut Proof LoadFred

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 5/11/2017