Summary for Test 2023-07-31-88-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994425 DEA: 040K5204 EFIS: 0416000098 |
---|---|
DIST-CO-RTE-PM | 04-SON-12-11.0/T17.4 |
Award Date | 03/21/2023 |
Closeout Date | Not set |
Work Description | Overlay with RHMA, replace guardrails, approach slabs and signs. |
Location Description | Construction on State Highway in Sonoma County from Llano Road to Farmers Lane. |
QA Service Level | 1 (Verified on 12/07/2022) |
Sample Information
Sample Taken Date | 07/31/2023 | Sample Unique Key | 88 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/01/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 RHMA-G |
The quantity of what the sample constitutes | 24 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Valdez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Dutra Materials Richmond | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 1 | HMA Mix Number |
Test Details
DIME Sample ID: 2023-07-31-88
DIME Test ID: 2023-07-31-88-1
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-02-14
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Anthony Valdez
Date of test: 08/01/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2048.2 g
Mass Loss: 175.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.69 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.72 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/14/2024 ✔