Summary for Test 2017-05-08-1-3
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 211690 DEA: 042A3204 EFIS: 0400000817 |
---|---|
DIST-CO-RTE-PM | 04-NAP-121-9.2/9.4 |
Award Date | 12/01/2016 |
Closeout Date | 01/23/2019 |
Work Description | ROADWAY WIDENING, BRIDGE REPLACEMENT, CREEK GRADING |
Location Description | NAPA COUNTY IN NAPA AT SILVERADO TRAIL ROAD |
QA Service Level | 1 (Verified on 01/03/2017) |
Sample Information
Sample Taken Date | 05/08/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/09/2017 |
Sample type | Quality Assurance | A brief description of the sample | 0.6 L/R 7 wire strand |
The quantity of what the sample constitutes | 1 coil each | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Stacey | Last name of sampler or witnessed by | Davis |
Title of sampler | QAI | Telephone number of sampler | 5624806984 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Kie-Con Antioch | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | |
---|---|---|---|
Reel/Coil/Pack Number(s) | S333792-6, S333795-6, S333797-6, S333798-6, S377587-5, S333778-6, S333784-6, S333785-6, S333788-6, S333796-6, S377590-1, S377617-5, S377573-1 | Number of Coils | 13 |
Group Number | Unknown | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0286190, S053616, S0286198, S026197, S0286193, S0286687, S0286194 | Mfg. Lot Number(s) | N/A |
Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2017-05-08-1
DIME Test ID: 2017-05-08-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2017-05-17
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/10/2017
UTM: 120KIP
Temperature: 72 F
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0286193 | S333788-6 | 0.217 | 59893 | 54763 | 27.7 | 1.75 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 5/10/2017 ✔