Summary for Test 2024-01-11-45-1
Test performed: CTM 214-August 2010Project Information
Project Identifiers | Project ID: 994164 DEA: 042J9504 EFIS: 0415000043 |
---|---|
DIST-CO-RTE-PM | 04-SCL-9,17,85,87,101,etc-VAR |
Award Date | 12/16/2022 |
Closeout Date | Not set |
Work Description | MODIFYING RAMP METERING SYSTEMS AND PLACE HMA (TYPE A). |
Location Description | SANTA CLARA COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 08/08/2022) |
Sample Information
Sample Taken Date | 01/11/2024 | Sample Unique Key | 45 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/26/2024 |
Sample type | Annual Source Testing | A brief description of the sample | 3/8 coarse aggregate |
The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Charles | Last name of sampler or witnessed by | Poolis |
Title of sampler | Caltrans TET | Telephone number of sampler | |
Laboratory sample identification | 24-ASC-0011 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Graniterock Aromas | Transportation Laboratory (TL) Number | C317-011124-3 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 00000000 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | A.R Wilson | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-01-11-45
DIME Test ID: 2024-01-11-45-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2024-02-12
Test Results
What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Bang Nguyen
Date of test: 02/12/2024
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 5.3 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/12/2024 ✔