Summary for Test 2024-01-11-28-3

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994856
DEA: 010H5604
EFIS: 0117000236
DIST-CO-RTE-PM01-HUM-299-0.0/R5.7
Award Date08/07/2023
Closeout DateNot set
Work DescriptionPLACE RHMA, REPLACE ASPHALT CONCRETE, AND CONCRETE BARRIER TRANSITION.
Location DescriptionHUMBOLDT COUNTY IN AND NEAR ARCATA FROM ROUTE 299/101 SEPARATION TO 0.2 MILE EAST OF BLUE LAKE UNDERCROSSING
QA Service Level1 (Verified on 06/08/2023)

Sample Information

Sample Taken Date01/11/2024 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/12/2024
Sample typeQuality Assurance A brief description of the sampleReady Mix Concrete
The quantity of what the sample constitutes 7 CY From where was the sample collectedJob Site
First name of sampler or witnessed byMike Last name of sampler or witnessed byThomas
Title of samplerASR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMercer Fraser - Fortuna Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameEssex UC

Material Information

Material TypeConcrete The concrete mix design numberMF CL 1 .45 SLAG
The truck number from where the sample was collected697 The batch plant ticket number from where the sample was collected51288
Concrete batch plant17 The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedready mix truck Where the material sample would have been placed if not sampledConcrete barrier transition
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-01-11-28
DIME Test ID: 2024-01-11-28-3
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-02-09

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Tom Brown
Date of test: 02/08/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 73360 lb
Maximum load on cylinder 2: 81620 lb
Maximum load on cylinder 3: 84850 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 6360 psi
General comments (publicly viewable) (Max 1000 characters): 28 Day Break 02/08/24

Test was verified on 2/9/2024