Summary for Test 2024-01-30-51-5

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/30/2024 Sample Unique Key51
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/02/2024
Sample typePreliminary A brief description of the sampleJMF PP
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byJesse Last name of sampler or witnessed byJesse
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34 M
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-01-30-51
DIME Test ID: 2024-01-30-51-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2024-02-09

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 02/08/2024
Time of test: 07:05 HH:MM
Test Temperature: 135 C
Speed: 50 rpm
Spindle size: 21 in
Torque: 95.6 %
Viscosity reading #1 (A) : 0.954 Pa-s
Viscosity reading #2 (B) : 0.954 Pa-s
Viscosity reading #3 (C): 0.959 Pa-s
Average viscosity: 0.956 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/9/2024