Summary for Test 2024-01-25-37-6
Test performed: CTM 226-July 2010Project Information
Project Identifiers | Project ID: 994296 DEA: 07336004 EFIS: 0716000375 |
---|---|
DIST-CO-RTE-PM | 07-VEN-118-R1.4/1.8 |
Award Date | 12/07/2022 |
Closeout Date | Not set |
Work Description | CONSTRUCT STORMWATER TREATMENT DEVICES. |
Location Description | IN VENTURA COUNTY NEAR SATICOY FROM 0.2 MILE EAST OF NARDO STREET TO 0.1 MILE WEST OF SANTA CLARA RIVER |
QA Service Level | 1 (Verified on 10/06/2022) |
Sample Information
Sample Taken Date | 01/25/2024 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/26/2024 |
Sample type | Department Acceptance | A brief description of the sample | PCC Aggregate |
The quantity of what the sample constitutes | 3 Bags of Aggregate | From where was the sample collected | Source |
First name of sampler or witnessed by | Avo | Last name of sampler or witnessed by | Karajian |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | National Ready Mix - Moorpark | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-56-0032 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Conveyor Belt | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-01-25-37
DIME Test ID: 2024-01-25-37-6
Testing Lab: CT D07 - Plant Services
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2024-02-05
Test Results
Input Type: Measured
Tester's full name: Avo Karajian
Date of test: 01/26/2024
Wet weight of the sample: 525.0000000000 grams
Dry weight of the sample: 490.0000000000 grams
Weight of water in sample: 35.0000000000 grams
Percent moisture: 7.1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/5/2024 ✔