Summary for Test 2023-05-10-99-2
Test performed: AASHTO T209-22
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
Project Identifiers | Project ID: 993333 DEA: 04264724 EFIS: 0419000068 |
---|---|
DIST-CO-RTE-PM | 04-MRN-101-R20.8/27.1 |
Award Date | 04/26/2022 |
Closeout Date | Not set |
Work Description | CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL. |
Location Description | MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE |
QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
Sample Taken Date | 05/10/2023 | Sample Unique Key | 99 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/11/2023 |
Sample type | Quality Assurance | A brief description of the sample | HMA |
The quantity of what the sample constitutes | 4 BOXES | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Valdez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Dutra Materials Richmond | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 11 | HMA Mix Number | l |
Test Details
DIME Sample ID: 2023-05-10-99
DIME Test ID: 2023-05-10-99-2
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-02-01
Test Results
Number of Samples: 2
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Anthony Valdez
Date of test: 02/01/2024
Method Performed: no data
Mass of container filled with water 1: 7389.4 grams
Mass of oven-dry sample in air for Sample 1: 1538.0 grams
Mass of container filled with the sample and water for Sample 1: 8313.9 grams
Mass of container filled with water 2: 7389.4 grams
Mass of oven-dry sample in air for Sample 2: 1561.1 grams
Mass of container filled with the sample and water for Sample 2: 8328.9 grams
Temperature of Water: 72 °F
Specific Gravity for Sample 1: 2.507
Specific Gravity for Sample 2: 2.511
Average Specific Gravity: 2.509
Theoretical maximum density at 25°C (77°F): 2502 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/1/2024 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.