Summary for Test 2023-08-10-91-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 994629 DEA: 020J5404 EFIS: 0219000134 |
---|---|
DIST-CO-RTE-PM | 02--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 08/07/2023) |
Sample Information
Sample Taken Date | 08/10/2023 | Sample Unique Key | 91 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/11/2023 |
Sample type | Preliminary | A brief description of the sample | Soil for culvert recommendation |
The quantity of what the sample constitutes | Culvert Recommendation C-4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Dan | Last name of sampler or witnessed by | Curran |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | D79318 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | In Situ | Transportation Laboratory (TL) Number | 824102 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-SIS-3-51.81, 35 ft. Rt of CL, 0.5 ft. below OG | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-08-10-91
DIME Test ID: 2023-08-10-91-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2024-01-30
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Dennis Hickey and S. McWithey
Date of test: 08/16/2023
Minimum soil resistance of the lab measurement: 4000 Ohms
Soil sample temperature: 19.9 C
Soil box constant: 1
pH of soil: 6.56
Minimum soil resistance corrected to 15.5: 4440.00 Ohm-cm
Minimum soil resistivity at 15.5: 4440 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=6.56, ρ=4440.Ω∙cm
Test was verified on 1/30/2024 ✔