Summary for Test 2023-12-29-14-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994443
DEA: 053307C4
EFIS: 0514000028
DIST-CO-RTE-PM05-SLO-41,46-44.5/45.3,54.0/57.8
Award Date02/27/2023
Closeout DateNot set
Work DescriptionWye Segment - Route 41/46 Separation
Location DescriptionNot set
QA Service Level1 (Verified on 12/16/2022)

Sample Information

Sample Taken Date12/29/2023 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/30/2023
Sample typeQuality Assurance A brief description of the sample4x8 Concrete Cylinders
The quantity of what the sample constitutesDS-23 - 3F36L005 From where was the sample collectedJob Site
First name of sampler or witnessed byKyle Last name of sampler or witnessed byEngen
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHolliday Rock Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameDS-23

Material Information

Material TypeConcrete The concrete mix design number3F36L005
The truck number from where the sample was collected734 The batch plant ticket number from where the sample was collected6
Concrete batch plantHolliday Rock Company The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedMix Truck Where the material sample would have been placed if not sampledDS-23
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-12-29-14
DIME Test ID: 2023-12-29-14-1
Testing Lab: CT D05 - Whitley Gardens Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-01-26

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Kyle Engen
Date of test: 01/26/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 60778 lb
Maximum load on cylinder 2: 56861 lb
Maximum load on cylinder 3: 59518 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 4835.2 psi
Compressive strength of cylinder 2: 4523.5 psi
Compressive strength of cylinder 3: 4734.9 psi
Compressive strength (to nearest 10 psi): 4700 psi
General comments (publicly viewable) (Max 1000 characters): 3600 psi spec

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
05-3307C4_CTM 521_KEE_231229_DS-23_28 Day_3x_1pdf247.25 KB01/26/20242023-12-29-14-1   Info

Test was verified on 1/26/2024