Summary for Test 2023-08-09-98-3

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 215157
DEA: 021H5704
EFIS: 0216000036
DIST-CO-RTE-PM02-SHA-299-67.8/77.8
Award Date02/09/2023
Closeout DateNot set
Work DescriptionBURNEY CAPM - PAVEMENT REHABILITATION
Location DescriptionBUNCH GRASS LOOKOUT RD TO NAPA LN
QA Service Level1 (Verified on 09/03/2020)

Sample Information

Sample Taken Date08/09/2023 Sample Unique Key98
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/09/2023
Sample typeProduction Start-Up A brief description of the sample1 bag of Combined RAP (3/8-inch)
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byRandy Last name of sampler or witnessed byCGI
Title of sampler Telephone number of sampler
Laboratory sample identificationD79314B Linked DIME Sample ID
The fabricator/manufacturer/facility nameJ.F. Shea Construction — Fawndale Rock and Asphalt (Redding, CA) Transportation Laboratory (TL) Number823602
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceFawndale Rock and Asphalt, Redding, CA
Aggregate Size3/8-inch Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix Number

Test Details

DIME Sample ID: 2023-08-09-98
DIME Test ID: 2023-08-09-98-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-01-25

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency and Josh Murphy
Date of test: 08/11/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.1 grams
Mass of oven-dry sample in air for Sample 1: 2587.6 grams
Mass of container filled with the sample and water for Sample 1: 8922.6 grams
Temperature of Water: 78 °F
Specific Gravity for Sample 1: 2.587
Theoretical maximum density at 25°C (77°F): 2579.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.587, Gser≈2.795

Test was verified on 1/25/2024