Summary for Test 2023-08-09-98-3
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 215157 DEA: 021H5704 EFIS: 0216000036 |
---|---|
DIST-CO-RTE-PM | 02-SHA-299-67.8/77.8 |
Award Date | 02/09/2023 |
Closeout Date | Not set |
Work Description | BURNEY CAPM - PAVEMENT REHABILITATION |
Location Description | BUNCH GRASS LOOKOUT RD TO NAPA LN |
QA Service Level | 1 (Verified on 09/03/2020) |
Sample Information
Sample Taken Date | 08/09/2023 | Sample Unique Key | 98 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/09/2023 |
Sample type | Production Start-Up | A brief description of the sample | 1 bag of Combined RAP (3/8-inch) |
The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Randy | Last name of sampler or witnessed by | CGI |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D79314B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | J.F. Shea Construction — Fawndale Rock and Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 823602 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Fawndale Rock and Asphalt, Redding, CA |
---|---|---|---|
Aggregate Size | 3/8-inch | Aggregate Source | |
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2023-08-09-98
DIME Test ID: 2023-08-09-98-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-01-25
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency and Josh Murphy
Date of test: 08/11/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.1 grams
Mass of oven-dry sample in air for Sample 1: 2587.6 grams
Mass of container filled with the sample and water for Sample 1: 8922.6 grams
Temperature of Water: 78 °F
Specific Gravity for Sample 1: 2.587
Theoretical maximum density at 25°C (77°F): 2579.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.587,
Gser≈2.795
Test was verified on 1/25/2024 ✔