Summary for Test 2024-01-04-25-2

Test performed: CTM 216-June 2011

Project Information

Project IdentifiersProject ID: 994869
DEA: 073237U4
EFIS: 0720000224
DIST-CO-RTE-PM07-VEN-150-13.3/19
Award Date03/27/2023
Closeout DateNot set
Work DescriptionPLACE HMA (TYPE A) AND COLD PLANE ASPHALT
Location DescriptionVENTURA COUNTY IN AND NEAR OJAI FROM BURNHAM ROAD TO GORHAM ROAD
QA Service Level1 (Verified on 06/26/2023)

Sample Information

Sample Taken Date01/04/2024 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/04/2024
Sample typeDepartment Acceptance A brief description of the sampleAggregate Base
The quantity of what the sample constitutes13 sq. yd. From where was the sample collectedJob Site
First name of sampler or witnessed byPhilip Last name of sampler or witnessed byMaquiran
Title of samplerMREA Telephone number of sampler(213) 358-1518
Laboratory sample identification24-0040 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCA Rasmussen Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedFrom various locations at Aggregate Base
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2024-01-04-25
DIME Test ID: 2024-01-04-25-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2024-01-24

Test Results


Is oversize material: No
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 01/04/2024
In-place wet density: 2.10
Highest adjust wet density: 2.19
% Moisture: 11.7 %
Optimum Moisture: 13.2 %
Relative compaction: 96
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/24/2024