Summary for Test 2024-01-14-6-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 994648
DEA: 070W3904
EFIS: 0722000045
DIST-CO-RTE-PM07-VEN-101-10.7/26.7
Award Date06/20/2023
Closeout DateNot set
Work DescriptionSLURRY SEAL.
Location DescriptionVENTURA COUNTY FROM CAMARILLO SPRINGS ROAD UNDERCROSSING IN CAMARILLO TO MAIN STREET UNDERCROSSING IN VENTURA
QA Service Level1 (Verified on 07/24/2023)

Sample Information

Sample Taken Date01/14/2024 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/14/2024
Sample typeAcceptance A brief description of the sampleISR-RSC
The quantity of what the sample constitutes140 cu. yd. approx. From where was the sample collectedJob Site
First name of sampler or witnessed byPhilip Last name of sampler or witnessed byMaquiran
Title of samplerMREA Telephone number of sampler(213) 358-1518
Laboratory sample identification24-0138 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSLC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-GBR
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedfrom volumetric concrete mixer truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-01-14-6
DIME Test ID: 2024-01-14-6-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-01-19

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 01/17/2024
Identification number: 24-0138
Width of specimen: 6.125 inch
Width of specimen 2: 6.0625 inch
Width of specimen 3: 6.125 inch
Depth of specimen: 6.125 inch
Depth of specimen 2: 6.0625 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 8284 lb
Maximum load applied 2: 7457 lb
Maximum load applied 3: 8030 lb
Curing history and apparent moisture condition of the specimen: Damp
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 680 psi
Modulus of rupture 2: 630 psi
Modulus of rupture 3: 670 psi
Modulus of rupture average: 660 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/19/2024