Summary for Test 2024-01-11-8-3

Test performed: ASTM A370-20

Project Information

Project IdentifiersProject ID: 994267
DEA: 07326204
EFIS: 0716000113
DIST-CO-RTE-PM07-LA-39-17.8
Award Date11/23/2022
Closeout DateNot set
Work DescriptionCONSTRUCT BRIDGE, PLACE STRUCTURAL STEEL AND CONCRETE BARRIER.
Location DescriptionLOS ANGELES COUNTY IN AZUSA AT SAN GABRIEL RIVER BRIDGE
QA Service Level1 (Verified on 10/06/2022)

Sample Information

Sample Taken Date01/11/2024 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/18/2024
Sample typeQuality Assurance A brief description of the sampleA325 HDG
The quantity of what the sample constitutesVarious From where was the sample collectedSource
First name of sampler or witnessed byWilliam Last name of sampler or witnessed byClifford
Title of samplerQA Inspector Telephone number of sampler7142674733
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCordova Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL78-002-24 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)76829-3
Heat Number(s)3121459, 8000010207, 128064 Nut Mfg. Lot Number(s)459484A
Washer Mfg. Lot Number(s)0123-596 Bolt SpecificationA325
Bolt Length(s)33" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1 1/2" Bolt Mfg. Lot Number76829-3
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2024-01-11-8
DIME Test ID: 2024-01-11-8-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2024-01-31

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 01/19/2024
UTM: 67kip
Temperature: 72 f
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1276829-30.4990.1968863112757917.4

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 1/31/2024