Summary for Test 2024-01-11-10-1

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 994267
DEA: 07326204
EFIS: 0716000113
DIST-CO-RTE-PM07-LA-39-17.8
Award Date11/23/2022
Closeout DateNot set
Work DescriptionCONSTRUCT BRIDGE, PLACE STRUCTURAL STEEL AND CONCRETE BARRIER.
Location DescriptionLOS ANGELES COUNTY IN AZUSA AT SAN GABRIEL RIVER BRIDGE
QA Service Level1 (Verified on 10/06/2022)

Sample Information

Sample Taken Date01/11/2024 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/18/2024
Sample typeQuality Assurance A brief description of the sampleA325 HDG
The quantity of what the sample constitutes96 From where was the sample collectedSource
First name of sampler or witnessed byWilliam Last name of sampler or witnessed byClifford
Title of samplerQA Inspector Telephone number of sampler7142674733
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCordova Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL78-002-24 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)44703A-A
Heat Number(s)100104702, 8000006661, 124423 Nut Mfg. Lot Number(s)456888A
Washer Mfg. Lot Number(s)1122-530 Bolt SpecificationA325
Bolt Length(s)4" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size7/8" Bolt Mfg. Lot Number447013A
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2024-01-11-10
DIME Test ID: 2024-01-11-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2024-01-26

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 01/18/2024
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A447013A0.875067484300.1910.00Wedge Tensileaauvinen

General comments (publicly viewable) (Max 1000 characters): Wedge Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 1/26/2024