Summary for Test 2023-12-11-51-6
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 209820 DEA: 04297634 EFIS: 0415000040 COOP: 042548 |
---|---|
DIST-CO-RTE-PM | 04-ALA-84,680-17.9/21 |
Award Date | 02/19/2021 |
Closeout Date | Not set |
Work Description | ROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION. |
Location Description | ALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84 |
QA Service Level | 1 (Verified on 11/04/2019) |
Sample Information
Sample Taken Date | 12/11/2023 | Sample Unique Key | 51 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/12/2023 |
Sample type | Quality Assurance | A brief description of the sample | Hot Mix Asphalt |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Mond | Last name of sampler or witnessed by | Osawaru |
Title of sampler | Assistant Resident Engineer | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Pleasanton Plant | Transportation Laboratory (TL) Number | C968242 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Lot 11 Sublot 15 | Structure unique identifier | |
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 11 |
Sublot number | 15 | HMA Mix Number | 220304 |
Test Details
DIME Sample ID: 2023-12-11-51
DIME Test ID: 2023-12-11-51-6
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-01-11
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Robert Lohman
Date of test: 12/14/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 2913.8 g
Mass of the specimen and specimen basket assembly prior to ignition: 4969.7 g
Mass of HMA Sample prior to ignition: 2055.9 g
Mass Loss: 120.3 g
Mass of aggregate remaining after ignition: 1935.6 g
Correction Factor (Percent by mass of HMA Specimen): 1.11 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 4.59 %
General comments (publicly viewable) (Max 1000 characters): Lot 11 Sublot 15
Test was verified on 1/11/2024 ✔