Summary for Test 2017-04-21-7-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/21/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/26/2017
Sample typeQuality Assurance A brief description of the sampleF1554 Grade 55 HDG Anchor Bolts
The quantity of what the sample constitutes12 From where was the sample collectedDistributor
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBlue Circle Transportation Laboratory (TL) NumberC953706
Inspector Lot Number from the Transportation Laboratory (TL) FormL5309617 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)PL16101305 266716 275015 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationF1554 Gr 55
Bolt Length(s)12, 31, 30, 24 Nut SpecificationNA
Washer SpecificationNA FinishF2329
Diameter/Size1-1/4, 1, 3/4, Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2017-04-21-7
DIME Test ID: 2017-04-21-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2017-05-11

Test Results


Number of Samples: 8
Input Type: Calculated
Tester's full name: Brian
Date of test: 04/28/2017
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1PL161013050.4990.1956609618255028.7Brian
2PL161013050.4990.1956597828269028.4Brian
32667160.4990.1956643378368029.7Brian
42667160.5020.1979656148438027.4Brian
52750150.350.0962682228889028.1Brian
62750150.3490.0957745169127027.4Brian
72750150.350.0962696918912028.1Brian
82750150.3510.0968715918918028.9Brian

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 5/4/2017