Summary for Test 2024-01-02-1-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 994296 DEA: 07336004 EFIS: 0716000375 |
---|---|
DIST-CO-RTE-PM | 07-VEN-118-R1.4/1.8 |
Award Date | 12/07/2022 |
Closeout Date | Not set |
Work Description | CONSTRUCT STORMWATER TREATMENT DEVICES. |
Location Description | IN VENTURA COUNTY NEAR SATICOY FROM 0.2 MILE EAST OF NARDO STREET TO 0.1 MILE WEST OF SANTA CLARA RIVER |
QA Service Level | 1 (Verified on 10/06/2022) |
Sample Information
Sample Taken Date | 01/02/2024 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/02/2024 |
Sample type | Department Acceptance | A brief description of the sample | Structural Backfill |
The quantity of what the sample constitutes | 1232 SF | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Michelangelo | Last name of sampler or witnessed by | Sese |
Title of sampler | TET | Telephone number of sampler | 310-345-6204 |
Laboratory sample identification | 24-0023 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Structural Backfill |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Various locations | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-01-02-1
DIME Test ID: 2024-01-02-1-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-01-02
Test Results
Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Michelangelo Sese
Date of test: 01/02/2024
Gage No.: 31104
Test No.: no data
Nuclear By: Michelangelo Sese
Non-Bias Plan No.: 3
Depth: 8
Material No.: no data
Material Type: Structural Backfill
Impact By: Michelangelo Sese
Standard Count Density: 2014 g/cc
Count or Density 1: 2.17 g/cc
Count or Density 2: 2.14 g/cc
Count or Density 3: 2.36 g/cc
Standard Count Moisture: 657 g/cc
Moisture Count 1: 0.22 g/cc
Moisture Count 2: 0.15 g/cc
Moisture Count 3: 0.18 g/cc
Sum of Count or Density: 6.67 g/cc
Average of Count or Density: 2.22 g/cc
Sum of Moisture Count: 0.55 g/cc
Average of Moisture Count: 0.18 g/cc
Calculated Percent Relative Compaction: 94.6 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters): VEN Rte. 118
Back Side of RW
Sta. 10+00 to Sta. 10+88
Test was verified on 1/2/2024 ✔