Summary for Test 2023-09-22-95-3

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 993192
DEA: 024H4404
EFIS: 0218000119
DIST-CO-RTE-PM02-PLU-70-0.0/29.9
Award Date02/10/2022
Closeout Date05/15/2024
Work DescriptionCONSTRUCT SOLDIER PILE RETAINING WALL, REPAIR RSP AND HMA PAVING.
Location DescriptionPLUMAS COUNTY AT VARIOUS LOCATIONS FROM BUTTE COUNTY LINE TO 3.1 MILES WEST OF ROUTE 89
QA Service Level1 (Verified on 08/23/2021)

Sample Information

Sample Taken Date09/22/2023 Sample Unique Key95
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/20/2023
Sample typeDepartment Acceptance A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutes1 of 2 cans From where was the sample collectedSource
First name of sampler or witnessed byTET Last name of sampler or witnessed bySloatermen
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAlbina Klamath Falls Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample0615 HMA SupplierQ&D
Certified Asphalt SupplierAlbina Asphalt (Klamath Falls Plant) - Klamath Falls OR MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2023-09-22-95
DIME Test ID: 2023-09-22-95-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2023-12-29

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 12/29/2023
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 34.317 kPa
Phase Angle (δ) (for the 10 cycles): 48.1 degree
Complex Modulus (G*) (for the 10 measurements): 3414.471 kPa
Test Temperature (Specimen 1): 22.0 C
(G*) x sin(δ)=: 2541 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 12/29/2023