Summary for Test 2023-07-17-74-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 993671
DEA: 07357704
EFIS: 0719000097
COOP: 075245
DIST-CO-RTE-PM07-LA-I-210-
Award Date02/14/2023
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level2 (Verified on 04/04/2022)

Sample Information

Sample Taken Date07/17/2023 Sample Unique Key74
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/17/2023
Sample typeQuality Control A brief description of the sample1x4 concrete aggregates
The quantity of what the sample constitutes1 per batch From where was the sample collectedSupplier
First name of sampler or witnessed bySebastian Last name of sampler or witnessed byAdams
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNational Ready Mix - Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0052
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedstockpile or belt cut
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-07-17-74
DIME Test ID: 2023-07-17-74-2
Testing Lab: Sequoia Consultants
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2023-12-28

Test Results


Number of tests: 2
Input Type: Calculated
Tester's full name: Joseph Lopez
Date of test: 07/18/2023
Temperature correction: 0
Temperature of solution: 77
Clay reading (test 1): 5.4
Sand reading (test 1): 4.7
Clay reading (test 2): 4.9
Sand reading (test 2): 4.3
Sand equivalent (test 1): 88
Sand equivalent (test 2): 88
Sand equivalent before temperature correction: 88
Sand equivalent after temperature correction: 88
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/28/2023