Summary for Test 2017-04-19-4-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211794 DEA: 044G5104 EFIS: 0412000483 |
---|---|
DIST-CO-RTE-PM | 04-SOL-80-31.4,32.6 |
Award Date | 01/20/2017 |
Closeout Date | 09/12/2019 |
Work Description | BRIDGE CONSTRUCTION |
Location Description | SOLANO COUNTY IN AND NEAR VACAVILLE AT MERIDIAN ROAD OVERCROSSING AND AT MIDWAY ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 01/03/2017) |
Sample Information
Sample Taken Date | 04/19/2017 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/24/2017 |
Sample type | Recertification | A brief description of the sample | Flash Welded Hoops |
The quantity of what the sample constitutes | 10 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
Title of sampler | QA | Telephone number of sampler | 9165170532 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Rebar Tracy CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-100-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4064129 |
Hoop Manufacturer Lot Number(s) | 0 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 6 |
Diameter of Hoop | 5'-0" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Arizona |
Welding Company | CMC Rebar (Tracy) | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-04-19-4
DIME Test ID: 2017-04-19-4-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2017-05-23
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/26/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | Cycle-6 | 100 | #6/19mm | S1910017, H & H Welder #H6020R | 0.44 | 41545 | 94420 | NECKING OK | Fred |
General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point FileTest was verified on 5/16/2017 ✔