Summary for Test 2023-12-12-2-9
Test performed: ASTM F606-21Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/12/2023 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/19/2023 |
Sample type | Quality Assurance | A brief description of the sample | ASTM F1554 Gr 55 Anchor Bolt |
The quantity of what the sample constitutes | 48 anchor bolts | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Henry | Last name of sampler or witnessed by | Arredondo |
Title of sampler | Caltrans Mets QA Inspector | Telephone number of sampler | 5623329603 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | A & M Nut & Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L166-131-23 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 3101912, 8000019550, 122538 | Nut Mfg. Lot Number(s) | Lot W000019430 |
Washer Mfg. Lot Number(s) | e3214 | Bolt Specification | ASTM F1554 gr 55 |
Bolt Length(s) | Nut Specification | ASTM A563 DH | |
Washer Specification | ASTM F436 | Finish | ASTM A153/ F2329 HDG |
Diameter/Size | 1" -8 x 36" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2023-12-12-2
DIME Test ID: 2023-12-12-2-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-12-29
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 12/20/2023
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 98334 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 12/29/2023 ✔