Summary for Test 2017-04-07-12-1

Test performed: AGGLP SIEVE_ANALYSIS-1

Project Information

Project IdentifiersProject ID: 212238
DEA: 11288824
EFIS: 1115000068
DIST-CO-RTE-PM11-SD-905,125,905-9.6/11.4
Award DateNot set
Closeout DateNot set
Work DescriptionCONSTRUCT FREEWAY TO FREEWAY CONNECTORS.
Location DescriptionSAN DIEGO COUNTY IN AND NEAR SAN DIEGO AT ROUTE 11/125/905 SEPARATION
QA Service Level1 (Verified on 03/20/2017)

Sample Information

Sample Taken Date04/07/2017 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/18/2017
Sample typeQuality Control A brief description of the sample125 SB CONN TO 905 SB FOUNDATION BENT NUMBER 2
The quantity of what the sample constitutes1 BAG From where was the sample collectedJob Site
First name of sampler or witnessed byJEFF Last name of sampler or witnessed byTESAR
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification17SOIL-0087 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNA Transportation Laboratory (TL) NumberC170413B
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedRC-17-63869
Where the material sample would have been placed if not sampled47 TO 70 FT

Test Details

DIME Sample ID: 2017-04-07-12
DIME Test ID: 2017-04-07-12-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-05-01

Test Results


Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 04/24/2017
Total mass of material in the sample: 2901 grams
Cumulative mass retained on the 2 in. sieve: 0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 0 grams
Cumulative mass retained on the 1/2 in. sieve: 0 grams
Cumulative mass retained on the 3/8 in. sieve: 0 grams
Cumulative mass retained on the #4 sieve: 0 grams
Cumulative mass retained on the #8 sieve: 0 grams
Total sample mass passing the #4 sieve: 816 grams
Total mass of fine material in the sample: 408 grams
Cumulative mass retained on the pan: 408 grams
Total cumulative mass of coarse aggregate: 0 grams
Total cumulative mass of fine aggregate: 408 grams
Sum of coarse and fine aggregate: 816 grams
Percentage of coarse material: 0 %
Percentage of fine material: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 100 %
Cumulative percent passing the #8 sieve: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/24/2017