Summary for Test 2023-12-15-26-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 215348 DEA: 060U4204 EFIS: 0616000004 |
---|---|
DIST-CO-RTE-PM | 06-FRE-99-R4.9/11.6 |
Award Date | 02/25/2021 |
Closeout Date | Not set |
Work Description | CONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION. |
Location Description | FRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 12/07/2020) |
Sample Information
Sample Taken Date | 12/15/2023 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/11/2023 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA - A R15 PG 70-10 |
The quantity of what the sample constitutes | 929 T | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Mills |
Title of sampler | Telephone number of sampler | 8033087727 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Ashlan | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 16 |
Sublot number | 5 | HMA Mix Number |
Test Details
DIME Sample ID: 2023-12-15-26
DIME Test ID: 2023-12-15-26-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-12-19
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 12/18/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 2874.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 5035.6 g
Mass of HMA Sample prior to ignition: 2161.6 g
Mass Loss: 103.8 g
Mass of aggregate remaining after ignition: 2057.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.36 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.30 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/19/2023 ✔