Summary for Test 2023-11-27-13-4
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994648 DEA: 070W3904 EFIS: 0722000045 |
---|---|
DIST-CO-RTE-PM | 07-VEN-101-10.7/26.7 |
Award Date | 06/20/2023 |
Closeout Date | Not set |
Work Description | SLURRY SEAL. |
Location Description | VENTURA COUNTY FROM CAMARILLO SPRINGS ROAD UNDERCROSSING IN CAMARILLO TO MAIN STREET UNDERCROSSING IN VENTURA |
QA Service Level | 1 (Verified on 07/24/2023) |
Sample Information
Sample Taken Date | 11/27/2023 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/30/2023 |
Sample type | Production Start-Up | A brief description of the sample | 3/4 " WMA-A-SP R15 0.50% EVO |
The quantity of what the sample constitutes | 8 Boxes of HMA | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | ESTEBAN | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0589A-23 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Sun Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 220826 SVA VLO |
Test Details
DIME Sample ID: 2023-11-27-13
DIME Test ID: 2023-11-27-13-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-12-18
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 12/01/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2112.0 g
Mass Loss: 103.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.26 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.05 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.59 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/18/2023 ✔