Summary for Test 2023-12-12-30-10

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 994102
DEA: 11430644
EFIS: 1119000045
DIST-CO-RTE-PM11-SD-905-12.0
Award Date10/28/2022
Closeout DateNot set
Work DescriptionCONSTRUCT WEIGH-IN-MOTION FACILITY, CRCP, HMA, AND RETAINING WALL.
Location DescriptionSAN DIEGO COUNTY NEAR SAN DIEGO AT OTAY MESA COMMERCIAL VEHICLE ENFORCEMENT FACILITY
QA Service Level1 (Verified on 08/24/2022)

Sample Information

Sample Taken Date12/12/2023 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/13/2023
Sample typeQuality Assurance A brief description of the sample3/4" HMA PSU
The quantity of what the sample constitutes12 boxes 3 bags From where was the sample collectedSource
First name of sampler or witnessed byJesse Last name of sampler or witnessed byFuentes
Title of sampler Telephone number of sampler
Laboratory sample identification8315-PSU Linked DIME Sample ID2023-12-12-29
The fabricator/manufacturer/facility nameVulcan Otay Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)N/A
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-12-12-30
DIME Test ID: 2023-12-12-30-10
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-01-17

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 12/15/2023
Cumulative Mass RetainedCumulative Percent Passing
6256 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
314.0 grams95 %
1367.0 grams78 %
2607.0 grams58 %
3632.0 grams42 %
715.9 grams
235.0 grams28 %
431.0 grams17 %
502.0 grams13 %
609.0 grams6 %
653.0 grams4 %
672.0 grams2.6 %
673 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/17/2024