Summary for Test 2023-12-12-29-3

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 994102
DEA: 11430644
EFIS: 1119000045
DIST-CO-RTE-PM11-SD-905-12.0
Award Date10/28/2022
Closeout DateNot set
Work DescriptionCONSTRUCT WEIGH-IN-MOTION FACILITY, CRCP, HMA, AND RETAINING WALL.
Location DescriptionSAN DIEGO COUNTY NEAR SAN DIEGO AT OTAY MESA COMMERCIAL VEHICLE ENFORCEMENT FACILITY
QA Service Level1 (Verified on 08/24/2022)

Sample Information

Sample Taken Date12/12/2023 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/13/2023
Sample typeQuality Assurance A brief description of the sample3/4" HMA PSU
The quantity of what the sample constitutes12 boxes 3 bags From where was the sample collectedSource
First name of sampler or witnessed byJesse Last name of sampler or witnessed byFuentes
Title of sampler Telephone number of sampler
Laboratory sample identification8315-PSU Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Otay Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number220817 Otay Val

Test Details

DIME Sample ID: 2023-12-12-29
DIME Test ID: 2023-12-12-29-3
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2024-01-17

Test Results


Number of tests: 3
Input Type: Measured
Tester's full name: Daniel Smith / J Seymour
Date of test: 12/14/2023
123
2.384 2.379 2.389
2.553

6.6 %

6.8 %

6.4 %

6.6 %
General comments (publicly viewable) (Max 1000 characters): Target 4.0% / +/- 1.5%

Test was verified on 1/17/2024