Summary for Test 2023-10-19-76-4
Test performed: AASHTO T269-14Project Information
Project Identifiers | Project ID: 994615 DEA: 112N1644 EFIS: 1122000151 |
---|---|
DIST-CO-RTE-PM | 11-IMP-8-R3.7/R48.0 |
Award Date | 05/19/2023 |
Closeout Date | 06/11/2024 |
Work Description | MICROSURFACING, COLD PLANE, RHMA, PAVEMENT MARKING, & CENSUS SYSTEMS. |
Location Description | IMPERIAL COUNTY AT VARIOUS LOCATIONS FROM 0.7 MILE EAST OF MOUNTAIN SPRINGS ROAD UNDERCROSSING TO 0.2 MILE EAST OF ROUTE 7/8 SEPARATION |
QA Service Level | 1 (Verified on 06/04/2024) |
Sample Information
Sample Taken Date | 10/19/2023 | Sample Unique Key | 76 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/20/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2" RHMA-G |
The quantity of what the sample constitutes | 4 boxes 4 bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Loper |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 9813-A | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | API Gateway | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 12 | HMA Mix Number | 1 |
Combined Gradation Report Information
Combined Gradation Report Id | Bin Index | Dime Test Id |
---|---|---|
No assigned tests for this sample. |
Test Details
DIME Sample ID: 2023-10-19-76
DIME Test ID: 2023-10-19-76-4
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2024-03-20
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Measured
Tester's full name: Daniel Smith / J Seymour
Date of test: 12/13/2023
1 | 2 | 3 | ||||
---|---|---|---|---|---|---|
2.310 | 2.311 | 2.314 | ||||
2.405 | ||||||
4.0 % | 3.9 % | 3.8 % | ||||
3.9 % |
General comments (publicly viewable) (Max 1000 characters): Complies Target 5.0% / +/-1.5% - Result - 3.9%
Test was verified on 3/20/2024 ✔