Summary for Test 2023-09-21-119-5
Test performed: CTM 504-June 2010Project Information
Project Identifiers | Project ID: 994325 DEA: 044J4904 EFIS: 0415000356 |
---|---|
DIST-CO-RTE-PM | 04-ALA-13-6.7/7.2 |
Award Date | 01/09/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT CONCRETE BARRIERS AND BARRIER SLAB, COLD PLANE AND OVERLAY. |
Location Description | ALAMEDA COUNTY IN OAKLAND FROM 0.2 MILE NORTH OF LINCOLN AVENUE OVERCROSSING TO 0.2 MILE SOUTH OF PARK BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 10/14/2022) |
Sample Information
Sample Taken Date | 09/21/2023 | Sample Unique Key | 119 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/22/2023 |
Sample type | Quality Assurance | A brief description of the sample | 4x8 concrete cylinders |
The quantity of what the sample constitutes | 6 cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Dustin | Last name of sampler or witnessed by | Seibert |
Title of sampler | Quality Control Technician | Telephone number of sampler | |
Laboratory sample identification | Set 1 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Ecoterra Ready Mix | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 7SK5K1X425F |
---|---|---|---|
The truck number from where the sample was collected | Load 3 | The batch plant ticket number from where the sample was collected | na |
Concrete batch plant | The fabricator/manufacturer designation for the sample | Set 1 | |
A detailed description of where the material sample was collected | S/B 13 south of Park Blvd | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-09-21-119
DIME Test ID: 2023-09-21-119-5
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Test Release Date: 2023-12-12
Test Results
Input Type: Calculated
Tester's full name: Dustin Siebert
Date of test: 09/21/2023
Air Content: 3 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/12/2023 ✔