Summary for Test 2023-11-28-43-3

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993905
DEA: 034H5814
EFIS: 0320000240
DIST-CO-RTE-PM03-SAC-5-27.6/29.5,30.4/34.3
Award Date02/28/2023
Closeout DateNot set
Work DescriptionROADWAY EXCAVATION, PLACE CL2 AB, HMA & RHMA, & MODIFY RAMP METERS.
Location DescriptionSACRAMENTO COUNTY IN AND NEAR SACRAMENTO FROM 0.5 MILES SOUTH OF ARENA BOULEVARD OVERCROSSING TO 0.4 MILES SOUTH OF 99/5 INTERCHANGE AND FROM 0.5 MILES NORTH OF THE 99/5 INTERCHANGE TO 0.4 MILE SOUTH OF THE YOLO COUNTY LINE
QA Service Level1 (Verified on 06/27/2022)

Sample Information

Sample Taken Date11/28/2023 Sample Unique Key43
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/08/2023
Sample typeQuality Assurance A brief description of the sampleBoxes of Mix
The quantity of what the sample constitutes3/4" HMA w/ 25% RAP From where was the sample collectedJob Site
First name of sampler or witnessed byDustan Last name of sampler or witnessed byKliethermes
Title of sampler Telephone number of sampler
Laboratory sample identification23-282 Linked DIME Sample ID2023-11-28-28
The fabricator/manufacturer/facility nameDe Silva Gates Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number2 HMA Mix Number

Test Details

DIME Sample ID: 2023-11-28-43
DIME Test ID: 2023-11-28-43-3
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-12-11

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 12/08/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2244.0 g
Mass Loss: 135.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.51 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.54 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/11/2023