Summary for Test 2023-12-01-27-1

Test performed: AASHTO T30-19

Project Information

Project IdentifiersProject ID: 214486
DEA: 080K1224
EFIS: 0815000244
DIST-CO-RTE-PM08-SBD-15-R28.6/37.5
Award DateNot set
Closeout DateNot set
Work DescriptionREHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT
Location DescriptionSAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date12/01/2023 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/01/2023
Sample typeQuality Assurance A brief description of the sampleCold Feed 3/4" AC Aggregate
The quantity of what the sample constitutes1 bag From where was the sample collectedFabricator
First name of sampler or witnessed byNATHAN Last name of sampler or witnessed byOGBASELIASIE
Title of samplerte Telephone number of sampler
Laboratory sample identificationtest 1 a100CY AT0849AM Linked DIME Sample ID853
The fabricator/manufacturer/facility nameSully Miller Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0068
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedAT THE JOBSITE
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design number300222 - CPC R25 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-12-01-27
DIME Test ID: 2023-12-01-27-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2023-12-08

Test Results


Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Calculated
Tester's full name: CHIJIOKE OKOROANYANWU
Date of test: 12/04/2023
Cumulative percent passing the 2 in. sieve: 0 %
Cumulative percent passing the 1 1/2 in. sieve: 0 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 88 %
Cumulative percent passing the 1/2 in. sieve: 71 %
Cumulative percent passing the 3/8 in. sieve: 64 %
Cumulative percent passing the #4 sieve: 46 %
Cumulative percent passing the #8 sieve: 38 %
Cumulative percent passing the #16 sieve: 29 %
Cumulative percent passing the #30 sieve: 19 %
Cumulative percent passing the #50 sieve: 11 %
Cumulative percent passing the #100 sieve: 8 %
Cumulative percent passing the #200 sieve: 4.8 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/8/2023