Summary for Test 2023-11-22-7-3

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/22/2023 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/27/2023
Sample typeQuality Assurance A brief description of the sample5/8 Hex Nuts
The quantity of what the sample constitutes16 of 16,200 From where was the sample collectedManufacturer
First name of sampler or witnessed byLorenzo Last name of sampler or witnessed byGarcia
Title of samplerQuality Assurance Inspector Telephone number of sampler17029172503
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBlue Circle Corporation Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL115-130-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)5805655306 Nut Mfg. Lot Number(s)38911-5805655306
Washer Mfg. Lot Number(s)N/A Bolt SpecificationN/A
Bolt Length(s)N/A Nut SpecificationASTM A194 Gr. 2H
Washer SpecificationN/A FinishASTM A153
Diameter/Size5/8 Bolt Mfg. Lot NumberN/A
Rocap Test Requirement(s) Lubricant Requirements(s)Blue Dye

Test Details

DIME Sample ID: 2023-11-22-7
DIME Test ID: 2023-11-22-7-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-12-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 12/06/2023
UTM: 400kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11C39733Proof Load

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 12/12/2023