Summary for Test 2023-10-20-79-2
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 994321 DEA: 040K1604 EFIS: 0416000044 |
---|---|
DIST-CO-RTE-PM | 04-ALA,CC-80-R7.6/8.0,0.0/13.5 |
Award Date | 02/08/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT RHMA, LIGHTING SYSTEM, AND CONCRETE BARRIER. |
Location Description | ALAMEDA AND CONTRA COSTA COUNTIES IN ALBANY AND CROCKETT FROM 0.4 MILE SOUTH OF ALAMEDA COUNTY LINE TO 0.2 MILE SOUTH OF POMONA STREET |
QA Service Level | 1 (Verified on 10/14/2022) |
Sample Information
Sample Taken Date | 10/20/2023 | Sample Unique Key | 79 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/22/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1 INCH x No. 4 |
The quantity of what the sample constitutes | N/A | From where was the sample collected | Source |
First name of sampler or witnessed by | IGNACIO | Last name of sampler or witnessed by | ARECHIGA |
Title of sampler | Telephone number of sampler | 5102077252 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Central Oakland Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | none |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Sample pick-up from Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | D20115EA | Lot number | |
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-10-20-79
DIME Test ID: 2023-10-20-79-2
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2023-12-05
Test Results
Number of tests: 1
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 10/22/2023
Temperature correction: 0
Temperature of solution: 71
Clay reading (test 1): 4
Sand reading (test 1): 3.4
Sand equivalent (test 1): 85
Sand equivalent before temperature correction: 0
Sand equivalent after temperature correction: 0
General comments (publicly viewable) (Max 1000 characters): PASSED
Central Oakland Plant
Test was verified on 12/5/2023 ✔