Summary for Test 2023-11-14-61-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 994579 DEA: 070W4004 EFIS: 0722000046 |
---|---|
DIST-CO-RTE-PM | 07-VEN-101-30.9/R36.3;R40.6/R43.6 |
Award Date | 05/16/2023 |
Closeout Date | Not set |
Work Description | CONCRETE PAVEMENT SLABS REPLACEMENT & SLURRY SHOULDER. |
Location Description | VENTURA COUNTY IN AND NEAR VENTURA FROM VENTURA RIVER BRIDGE TO 0.4 MILE SOUTH OF PADRE JUAN CANYON ROAD OVERCROSSING AND FROM 0.4 MILE NORTH OF PUNTA GORDA PEDESTRIAN UNDERCROSSING TO BATES ROAD UNDERCROSSING. |
QA Service Level | 1 (Verified on 07/24/2023) |
Sample Information
Sample Taken Date | 11/14/2023 | Sample Unique Key | 61 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/15/2023 |
Sample type | Department Acceptance | A brief description of the sample | CTS - RSC Aggregate |
The quantity of what the sample constitutes | 2 bags of aggregate | From where was the sample collected | Source |
First name of sampler or witnessed by | Avo | Last name of sampler or witnessed by | Karajian |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Short Load Concrete Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0046 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-11-14-61
DIME Test ID: 2023-11-14-61-1
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-12-05
Test Results
What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Avo Karajian
Date of test: 11/15/2023
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 98 %
Cumulative percent passing the 3/4 in. sieve: 77 %
Cumulative percent passing the 1/2 in. sieve: 44 %
Cumulative percent passing the 3/8 in. sieve: 18 %
Cumulative percent passing the #4 sieve: 6 %
Cumulative percent passing the #8 sieve: 2 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/5/2023 ✔