Summary for Test 2017-03-18-1-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 209384
DEA: 04264094
EFIS: 0400000735
COOP: 042531
DIST-CO-RTE-PM04-,SON--
Award Date01/21/2016
Closeout Date06/03/2020
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 06/03/2020)

Sample Information

Sample Taken Date03/18/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/03/2017
Sample typeQuality Assurance A brief description of the sample2 6x12 concrete cylinders
The quantity of what the sample constitutes205 CY From where was the sample collectedJob Site
First name of sampler or witnessed byK Last name of sampler or witnessed byIwamoto
Title of samplerTEC Telephone number of sampler510) 385-7179
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameShamrock Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier270119
Structure nameSan Antonio Creek Bridge

Material Information

Material TypeConcrete The concrete mix design number4201a
The truck number from where the sample was collected1414 The batch plant ticket number from where the sample was collected448818
Concrete batch plant04 The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedCHUTE FROM TRUCK Where the material sample would have been placed if not sampledAbutment 1 Seat Return Walls
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2017-03-18-1
DIME Test ID: 2017-03-18-1-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-04-17

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 04/17/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 145567 lb
Maximum load on cylinder 2: 145817 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 30 days
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 5182.2 psi
Compressive strength of cylinder 2: 5191.1 psi
Compressive strength (to nearest 10 psi): 5190 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 4/17/2017