Summary for Test 2023-07-13-81-3
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 993339 DEA: 024H9304 EFIS: 0219000027 |
---|---|
DIST-CO-RTE-PM | 02-SHA-299-44.3/44.9 |
Award Date | 07/13/2022 |
Closeout Date | 04/11/2024 |
Work Description | INGOT CURVE IMPROVEMENT - CURVE IMROVEMENT |
Location Description | IN SHASTA COUNTY NEAR INGOT FROM 2.7 MILES EAST OF SEAMANS GULCH ROAD TO 1.2 MILES WEST OF DU BOIS ROAD. |
QA Service Level | 1 (Verified on 11/22/2021) |
Sample Information
Sample Taken Date | 07/13/2023 | Sample Unique Key | 81 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/14/2023 |
Sample type | Production Start-Up | A brief description of the sample | 2 bags of Combined RAP (1/2-inch) |
The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D79298B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 858124 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Northstate Asphalt |
---|---|---|---|
Aggregate Size | 1/2-inch | Aggregate Source | |
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2023-07-13-81
DIME Test ID: 2023-07-13-81-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-11-28
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 07/17/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.7 grams
Mass of oven-dry sample in air for Sample 1: 1604.2 grams
Mass of container filled with the sample and water for Sample 1: 8310.1 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.547
Theoretical maximum density at 25°C (77°F): 2539.6 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.547,
Gser≈2.775
Test was verified on 11/28/2023 ✔