Summary for Test 2023-07-11-97-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 993339
DEA: 024H9304
EFIS: 0219000027
DIST-CO-RTE-PM02-SHA-299-44.3/44.9
Award Date07/13/2022
Closeout Date04/11/2024
Work DescriptionINGOT CURVE IMPROVEMENT - CURVE IMROVEMENT
Location DescriptionIN SHASTA COUNTY NEAR INGOT FROM 2.7 MILES EAST OF SEAMANS GULCH ROAD TO 1.2 MILES WEST OF DU BOIS ROAD.
QA Service Level1 (Verified on 11/22/2021)

Sample Information

Sample Taken Date07/11/2023 Sample Unique Key97
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/11/2023
Sample typeProduction Start-Up A brief description of the sampleLime Treated 3/4-inch Type A Aggregate
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byCindy Last name of sampler or witnessed byBryant
Title of sampler Telephone number of sampler
Laboratory sample identificationD79296F Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis – Northstate Asphalt (Redding, CA) Transportation Laboratory (TL) Number853402
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0057::Shasta Ranch Aggregates (Anderson, CA)
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedMathematically Combined Gradation per CT 384
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-07-11-97
DIME Test ID: 2023-07-11-97-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2023-11-20

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 11/20/2023
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 99 %
Cumulative percent passing the 1/2 in. sieve: 88 %
Cumulative percent passing the 3/8 in. sieve: 67 %
Cumulative percent passing the #4 sieve: 41 %
Cumulative percent passing the #8 sieve: 28 %
Cumulative percent passing the #16 sieve: 19 %
Cumulative percent passing the #30 sieve: 14 %
Cumulative percent passing the #50 sieve: 10 %
Cumulative percent passing the #100 sieve: 7 %
Cumulative percent passing the #200 sieve: 5.4 %
General comments (publicly viewable) (Max 1000 characters): CT 384: Combined at 76.0% virgin aggregate from cold feed and 24.0% reclaimed aggregate from RAP; P1″=100.%, P¾″=99%, P½″=88%, P№4=41%, P№8=28%, P№30=14%, P№200=5.4%

Test was verified on 11/20/2023