Summary for Test 2023-07-11-96-3
Test performed: AASHTO T30-19Project Information
Project Identifiers | Project ID: 993339 DEA: 024H9304 EFIS: 0219000027 |
---|---|
DIST-CO-RTE-PM | 02-SHA-299-44.3/44.9 |
Award Date | 07/13/2022 |
Closeout Date | 04/11/2024 |
Work Description | INGOT CURVE IMPROVEMENT - CURVE IMROVEMENT |
Location Description | IN SHASTA COUNTY NEAR INGOT FROM 2.7 MILES EAST OF SEAMANS GULCH ROAD TO 1.2 MILES WEST OF DU BOIS ROAD. |
QA Service Level | 1 (Verified on 11/22/2021) |
Sample Information
Sample Taken Date | 07/11/2023 | Sample Unique Key | 96 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/11/2023 |
Sample type | Production Start-Up | A brief description of the sample | Combined RAP |
The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D79296B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Tullis – Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 853402 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Northstate Asphalt |
---|---|---|---|
Aggregate Size | 1/2-inch | Aggregate Source | |
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2023-07-11-96
DIME Test ID: 2023-07-11-96-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2023-11-20
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: Yes
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 07/18/2023
Cumulative Mass Retained | Correction Factor | Cumulative Percent Passing | ||||
---|---|---|---|---|---|---|
1436.4 grams | ||||||
0.0 grams | 0.0 % | 100 % | ||||
0.0 grams | 0.0 % | 100 % | ||||
0.0 grams | 0.0 % | 100 % | ||||
45.5 grams | 0.2 % | 97 % | ||||
198.0 grams | 0.2 % | 86 % | ||||
397.5 grams | -1.0 % | 71 % | ||||
707.4 grams | -0.4 % | 50 % | ||||
901.8 grams | -0.4 % | 37 % | ||||
1043.3 grams | -0.5 % | 27 % | ||||
1145.6 grams | -0.8 % | 19 % | ||||
1224.4 grams | -0.7 % | 14 % | ||||
1283.3 grams | -0.8 % | 10 % | ||||
1324.5 grams | -0.6 % | 7.2 % | ||||
1332.8 grams |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/20/2023 ✔