Summary for Test 2023-09-18-77-4

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994603
DEA: 09392404
EFIS: 0922000037
DIST-CO-RTE-PM09-KER-14,58-Var
Award Date04/21/2023
Closeout Date12/22/2023
Work DescriptionHOT MIX ASPHALT (TYPE A), REMOVE ASPHALT CONCRETE PAVEMENT, STRIPING.
Location DescriptionKERN COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 12/22/2023)

Sample Information

Sample Taken Date09/18/2023 Sample Unique Key77
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/02/2023
Sample typeProduction Start-Up A brief description of the sample3/4" HMA-A R25
The quantity of what the sample constitutes21 BOXES OF HMA, 2 BAGS OF AGGS, 4 QTS OF OIL From where was the sample collectedManufacturer
First name of sampler or witnessed byELI DONT Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0503A-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite, Arvin Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number1468

Test Details

DIME Sample ID: 2023-09-18-77
DIME Test ID: 2023-09-18-77-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-11-17

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 10/03/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2154.0 g
Mass Loss: 115.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.37 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.83 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/17/2023